Position
the snack machine in its place of operation no further than nine (9) feet
from the power outlet or receptacle and check that the door will open fully
without interference. Leave at least six (6) inches of space between the back
of the vending machine and any wall or obstruction for proper air
circulation.
Level the vending machine, making sure all levelers are touching the floor.
The snack machine must be level for proper operation and acceptance of
coins through the coin mechanism.
Retrieve the keys to the vending machine from the coin return cup. Open outer
door and remove all internal packing material.
Consult local, state and federal codes and regulations before installation of
the vending equipment.
|
|
Refer to the Safety Manual and Installation Guidelines manual (PIN
4206816) that shipped in the service package with your machine.
Before
connecting the snack vendor, the integrity of the main electrical supply must
be checked for correct polarity, presence of ground (earth) and correct
voltage. These checks should be repeated at six (6) month intervals with the
routine safety electrical testing of the vendor itself.
If the receptacle is not properly grounded or polarized, you should contact a
licensed electrician to correctly polarize and/or ground the receptacle to
ensure safe operation.
A noise suppressor has been installed in this machine to compensate for any
mains signal noise that could interfere with the normal operation of the snack
machine controller.
For proper operation of any vending equipment utilizing electronically controlled
components, the vending machine should be placed on an isolated or dedicated
noise free circuit, properly polarized and grounded.
Refer to Electrical Specifications on this sheet to determine circuit
amperage and protection.
|